Electrohydrodynamics of Nanometric Dispersed Systems
West University of Timisoara
Short link:
https://eeris.eu/
ERIF-2000-000R-0959
280
Visits
1. Equipments for the recovery of useful materials from granular waste, based on the action of eddy currents - Laboratory Separators 2. Microscope Nanosight based on NTA method for determining the dimensions and concentration of nanoparticles in a liquid suspension, 3. Optical metallographic microscope, 4. Air particle counter, 5. Comsol multiphysics software, 6. Adjustable low voltage DC power supply sources 0-100V/5A, 7. Adjustable low voltage DC power supply source 0-80V/100A, 8. Adjus...
Mihail
Lungu
mihail.lungu@e-uvt.ro
Dr.
SCIENTIFIC TEAM
1
Mihail LUNGU
View profile
Micro and Nanotechnology Facilities
RI Domain of activity
Cross-Disciplinary Centres in Mathematics
RI Domain of activity
Materials Synthesis or Testing Facilities
RI Domain of activity
Electrodynamic separation of useful materials from granular wastes, Magnetorheologycal systems, Smart nano-microsystems
RI Domain of activity
Research Data Management Plan:
No information available
Access Policy to Research Infrastructure and Related Services:
No information available
Research Services
Separation of small nonferrous particles from granular wastes
SERVICE DESCRIPTION:
Eddy-currents separation techniques, designed for recovery from heterogeneous mixtures of small nonferrous particles having dimensions less than 5 mm, by using different separators with moving permanent magnets: Inclined disk eddy currents separator, Angular drum eddy currents separator, Air-water eddy currents separator.
SERVICE PERSONS:
Mihail LUNGU
View profile
ACCESS THIS SERVICE
You need to be logged in to request access to this service. Click
here
to login.
If you don’t have an ERRIS account yet, please register
here
.
Dielectrophoretic manipulation of nanoparticles in fluid media
SERVICE DESCRIPTION:
SERVICE PERSONS:
ACCESS THIS SERVICE
You need to be logged in to request access to this service. Click
here
to login.
If you don’t have an ERRIS account yet, please register
here
.
Nanoparticle analysis in in biphasic fluid media suspensions
SERVICE DESCRIPTION:
SERVICE PERSONS:
ACCESS THIS SERVICE
You need to be logged in to request access to this service. Click
here
to login.
If you don’t have an ERRIS account yet, please register
here
.
Research Equipment
Nanoparticles tracking analysis LM 10 system
CATALOG NAME:
NanoSight LM 10
DESCRIPTION:
NanoSight LM series are newly developed devices designed to determine the size distribution and numbers of nanoparticles in polydisperse and heterogeneous systems, such as systems that are partially aggregated. The analyzer uses a CCD or Scientific CMOS camera mounted on an optical microscopic system to track light scattered by particles that are present in a focused (80 mm) laser beam generated by a single-mode laser diode. The Brownian motion of the nanoparticles is tracked at 30 frames s-1. Dedicated image analysis software is employed to evaluate mean squared displacements of each visible particle, which are used to determine sizes based on the Stokes Einstein equation.
PRODUCER:
Nanosight Ltd. England
PRODUCTION YEAR:
2012
COMMISSIONING DATE:
PRICE RANGE (at the time of purchase)
DATA SHEET:
Download data sheet file (13.25 kb)
AC Induction Hysteresigraph MHE-02
CATALOG NAME:
MHE-02
DESCRIPTION:
maximum field capability: 6lOe (0.6 Tesla) working frequency: 50 Hz (10Hz...500Hz range avatlable) maximum intrinsic sensitivity: 1.39E-7 Wb/V minimum magnetic sample mass: 30mg precision: better than 1.5% FS on both measurin channels PC-aided 16bit DAQ and numeric signal processing
PRODUCER:
PRODUCTION YEAR:
COMMISSIONING DATE:
PRICE RANGE (at the time of purchase)
DATA SHEET:
Air-water eddy currents separator with permanent magnets
CATALOG NAME:
Manufactured laboratory equipment
DESCRIPTION:
A new eddy-currents separation technique, based on a complementary air-water method, designed for recovery from heterogeneous mixtures of small nonferrous particles having dimensions less than 5 mm. The new equipment contains as main part a horizontal magnetized rotary cylinder with four poles of NdFeB permanent magnets, alternately N-S and S-N oriented. The separation process occurs under successive and complementary actions: first the electromagnetic forces act upon strongly conducting nonferrous particles in air, then electromagnetic and Magnus forces upon poorly conducting and undecided particles in water.
PRODUCER:
Faculty of Physics, West University of Timisoara
PRODUCTION YEAR:
2016
COMMISSIONING DATE:
PRICE RANGE (at the time of purchase)
DATA SHEET:
Phone:
+40 745604078
Fax:
40256592108
Bd. V. Parvan
,
4
,
Timisoara
300223
,
Timis
Romania
Loading Infrastructure