LABORATORY FOR PHYSICO-CHEMICAL CHARACTERIZATION, ANALYSIS AND TESTING OF MICRO- AND NANOSTRUCTURED HYBRID MATERIALS
National Research and Development Institute for Chemistry and Petrochemistry-ICECHIM
Short link:
https://eeris.eu/
ERIF-2000-000C-0766
1730
Visits
Initiating of this laboratory was possible with the support offered by the European project FP6-2004-ACC-SSA-2, acronym ENPONA. The main ACTIVITIES of laboratory are focused on micro- and nanostructured materials, components, products and innovative processes, used in: medicine, biotechnology, renewable energy, food, agriculture, textiles, electronics and environmental applications. Main APPLICATIONS include: drug delivery systems, controlled release systems for bioactive substances, biosensor...
Cristian
PETCU
cristian.petcu@icechim-pd.ro
Dr.ing.
SCIENTIFIC TEAM
5
Elvira ALEXANDRESCU
View profile
Ioana Catalina GÎFU
View profile
Raluca IANCHIS
View profile
Claudia Mihaela NINCIULEANU
View profile
Cristina NISTOR
View profile
Micro and Nanotechnology Facilities
RI Domain of activity
Materials Synthesis or Testing Facilities
RI Domain of activity
Analytical Facilities
RI Domain of activity
Heterogeneous Systems
RI Domain of activity
Research Data Management Plan:
No information available
Access Policy to Research Infrastructure and Related Services:
No information available
Research Services
Chemical composition and structure analyses
SERVICE DESCRIPTION:
Laboratory can provide analyses of composition and structure for a wide range of materials, using FT-IR, UV-Vis and Laser Doppler Electrophoresis (LDE) techniques. Measurement methods available for the analysis of liquids or solids using FT-IR spectrometer (TENSOR 37, Bruker) are: - Transmission using KBr pellet. Applications: high absorptive samples, powders, refracting or opaque solids, liquids, air sensitive samples; - Attenuated Total Reflection with Golden Gate diamond ATR unit. Applications: fine particles, powders, thin films, liquids, simple & coated fibers, metallic alloys, thin layers depositions of different types of supports; - Low volume liquid cell (CaF2 window, 1-3 µL sample volume). Applications: liquids, high absorptive samples. UV-Vis spectrometer (NICOLET EVOLUTION 500) is an instrument with double beams (reference and sample beams), applicable to the analysis of samples in two modes: - Using high precision cells (made of special optical glass or quartz). Applications: qualitative analysis (identified of organic compounds or liquids, if any recorded data is available) and/or quantitative analysis; - Using solid membrane. Applications: thin films, thin layers depositions of different types of supports (plastic, glass). Measurement of Zeta potential of micro- and nanoparticles (dispersed in water or organic solvents) is performed by LDE technique. A ZETASIZER NANO ZS 3600 instrument is used for analyzing the stable dispersions of particles having their average hydrodynamic diameter in the range 5 – 10000 nm. Zeta potential is an important and useful indicator of the electronic charge of particles in contact with a liquid, which can be used to predict and control the stability of colloidal suspensions or emulsions. The measurement of Zeta potential is often the key to understanding dispersion and aggregation processes in applications as diverse as water purification, ceramic slip casting and the formulation of paints, inks and cosmetics.
SERVICE PERSONS:
Claudia Mihaela NINCIULEANU
View profile
ACCESS THIS SERVICE
You need to be logged in to request access to this service. Click
here
to login.
If you don’t have an ERRIS account yet, please register
here
.
Granulometric characterizations
SERVICE DESCRIPTION:
Laboratory can provide nanoparticles dimensional analysis, performed by Dynamic Light Scattering (diffusion method), in the range 0.6 – 6 000 nm. The average hydrodynamic diameter and size distribution of spherical nanoparticles dispersed in water or organic solvents can be evaluated. ZETASIZER NANO ZS 3600 instrument (Malvern International Ltd) is used for analyzing the colloidal dispersions. Size measurement angle is 173º, which allows a sample concentration rage of 0.1ppm (0.00001vol %) – 40wt%. Applications: Analysing the stability of nanostructured particles in colloidal solutions (e.g. latexes, pigments, liquid inks, proteins, liposome, and inorganic particles). Advantages of the method: only small amounts of samples (powders) and reagents are necessary.
SERVICE PERSONS:
Cristina NISTOR
View profile
ACCESS THIS SERVICE
You need to be logged in to request access to this service. Click
here
to login.
If you don’t have an ERRIS account yet, please register
here
.
Morphology characterizations
SERVICE DESCRIPTION:
Using Quanta 200 Scanning Electron Microscope (SEM), we offer microscopy studies for a variety of specimens such as: polymers, ceramics, metals, alloys, composites, biological materials (insects, animal tissues, bacteria, viruses). We provide high resolution imaging (magnifications of over 100 000x) in a digital format for a wide range of samples: - conventional samples (using High Vacuum model; pressure under 1.3 Pa); - liquid and hydrated samples, oily, hot/ outgassing or dirty non-conductive samples, in their natural state (using ESEM mode; pressure 130-2600 Pa); - uncoated, non-conductive or partially conductive samples (using Low vacuum mode; pressure 10-130 Pa). Also, the Peltier cold stage allows wetting/ freezing of the sample using the ESEM mode pressure range at different temperatures (-20 ÷ 80 °C). Thus, we analyze diverse types of samples such as: sheets (thin films), powders, bulk or sectioned materials.
SERVICE PERSONS:
Elvira ALEXANDRESCU
View profile
ACCESS THIS SERVICE
You need to be logged in to request access to this service. Click
here
to login.
If you don’t have an ERRIS account yet, please register
here
.
Testings by Dynamic Mechanical Analysis
SERVICE DESCRIPTION:
Dynamic mechanical analysis (DMA) is a thermal analysis technique that measures the properties of materials as they are deformed under periodic stress. Specifically, in DMA a variable sinusoidal stress is applied, and the resultant sinusoidal strain is measured. However, most real-world materials including polymers are viscoelastic and exhibit a phase difference between those extremes. This phase difference, together with the amplitudes of the stress and strain waves, is used to determine a variety of fundamental material parameters, including storage and loss modulus, tan δ, complex and dynamic viscosity, storage and loss compliance, transition temperatures, creep, and stress relaxation, as well as related performance attributes such as rate and degree of cure, sound absorption and impact resistance, and morphology. One important application of DMA is measurement of the glass transition temperature of polymers. Amorphous polymers have different glass transition temperatures, above which the material will have rubbery properties instead of glassy behavior and the stiffness of the material will drop dramatically with an increase in viscosity. At the glass transition, the storage modulus decreases dramatically and the loss modulus reaches a maximum. Temperature-sweeping DMA is often used to characterize the glass transition temperature of a material. Varying the composition of monomers and cross-linking can add or change the functionality of a polymer that can alter the results obtained from DMA. An example of such changes can be seen by blending ethylene-propylene-diene monomer (EPDM) with styrene-butadiene rubber (SBR) and different cross-linking or curing systems.
SERVICE PERSONS:
Ioana Catalina GÎFU
View profile
ACCESS THIS SERVICE
You need to be logged in to request access to this service. Click
here
to login.
If you don’t have an ERRIS account yet, please register
here
.
Thermal behavior analyses of micro and nanostructured materials
SERVICE DESCRIPTION:
Laboratory can provide thermal analysis, such as TGA, DSC, TGA-DSC coupled with a Mass Spectrometer, for a variety of liquid and solid specimens: polymers, ceramics, metals, alloys, composites, thermoplastics, thermosets, elastomers, plastic films, fibers, coatings, paints, etc. Differential scanning calorimetry (DSC) can be used to measure a number of characteristic properties of a sample. Using this technique it is possible to observe fusion and crystallization events as well as glass transition temperatures Tg. This type of analysis can also be used to study oxidation and other chemical phenomena, such as cross-linking. Thermogravimetric analysis (TGA) can provide information about physical phenomena, such as second-order phase transitions, including vaporization, sublimation, absorption, adsorption, and desorption. Likewise, TGA can provide information about chemical phenomena including chemisorptions, dehydration, decomposition, and solid-gas reactions (e.g., oxidation or reduction). TGA is commonly used to determine selected characteristics of materials that exhibit either mass loss or gain due to decomposition, oxidation or loss of volatiles (such as moisture). Common applications of TGA are: - materials characterization through analysis of characteristic decomposition patterns; - studies of degradation mechanisms and reaction kinetics; - determination of organic content in a sample; - determination of inorganic (e.g. ash) content in a sample. Mass Spectrometer (MS) employed in conjunction with thermal analysis provides speciation of evolved species as function of temperature and time to provide an extremely powerful technique for the characterization of materials and their interactions and reactions with their environment. This system has significant advantages as in many applications it is desirable to carry out thermal analysis in inert, oxidizing, reducing or self-generated atmospheres.
SERVICE PERSONS:
Raluca IANCHIS
View profile
ACCESS THIS SERVICE
You need to be logged in to request access to this service. Click
here
to login.
If you don’t have an ERRIS account yet, please register
here
.
Research Equipment
Environmental Scanning Electron Microscope (ESEM)
CATALOG NAME:
FEI Quanta 200
DESCRIPTION:
The Quanta 200 Environmental Scanning Electron Microscope (ESEM) produces enlarged images of a variety of specimens, achieving magnifications of over 100000x providing high resolution imaging in a digital format. This important and widely used analytical tool provides exceptional depth of field, minimal specimen preparation, and the ability to combine the technique with X-ray microanalysis.
PRODUCER:
FEI Company
PRODUCTION YEAR:
2005
COMMISSIONING DATE:
PRICE RANGE (at the time of purchase)
DATA SHEET:
Download data sheet file (150.52 kb)
Zetasizer Nano ZS 3600
CATALOG NAME:
Zetasizer Nano ZS 3600
DESCRIPTION:
The Zetasizer Nano performs size measurements using a process called DLS - Dynamic Light Scattering (also known as PCS - Photon Correlation Spectroscopy). DLS measures Brownian motion and relates this to the size of the particles. It does this by illuminating the particles with a laser and analyzing the intensity fluctuations in the scattered light. It also calculates the zeta potential by determining the Electrophoretic Mobility and then applying the Henry equation. The electrophoretic mobility is obtained by performing an electrophoresis experiment on the sample and measuring the velocity of the particles using "Laser Doppler Velocimetry" (LDV).
PRODUCER:
Malvern Instruments
PRODUCTION YEAR:
2005
COMMISSIONING DATE:
PRICE RANGE (at the time of purchase)
DATA SHEET:
Download data sheet file (53.22 kb)
Thermogravimetric analysis (TGA)
CATALOG NAME:
TA Q5000 IR
DESCRIPTION:
TGA is particularly useful for the following measurements: Thermal stability, Decomposition kinetics, Composition, Estimated lifetime, Oxidative stability, Moisture and volatile contents. This instrument can be used for: characterization of hydrates, accurate residuals and quantification of filler content, faster separations, flame retardant test and simplified Curie point temperature calibration. Special heating mode: Hi-Res TGA and Modulated TGA.
PRODUCER:
TA Instruments
PRODUCTION YEAR:
2008
COMMISSIONING DATE:
PRICE RANGE (at the time of purchase)
DATA SHEET:
Download data sheet file (59.42 kb)
Differential Scanning Calorimetry Analysis (DSC)
CATALOG NAME:
TA Q2000
DESCRIPTION:
DSC instrumentation is of the "Heat Flux" design whereby the sample and reference are measured in the same furnace, on separate stages. The DSC employs area temperature detectors directly beneath the sample and reference positions, not platinum resistance thermometers or thermopiles. The DSC furnace is constructed of silver, with platinum heater windings. The benefit of this design is in the uniform thermal environment, and long furnace lifetime. Instrument has a robotic autosampler. Autosampler is able to load no less than 50 sample pans and no less than 5 reference pans in one tray.
PRODUCER:
TA Instruments
PRODUCTION YEAR:
2008
COMMISSIONING DATE:
PRICE RANGE (at the time of purchase)
DATA SHEET:
Download data sheet file (51.23 kb)
Simultaneous DSC and TG Analysis coupled with Mass Spectrometer (SDT-MS)
CATALOG NAME:
TA Q600
DESCRIPTION:
The Q600 Simultaneous DSC-TGA delivers a true, quantitative DSC signal. This signal is measured as the difference between the sample and inert reference as both are subject to the same temperature and atmospheric environment. Furnace compatible with devices for evolved gas analysis such as TA Instruments Evolved Gas Analyzer, based on a quadrapole mass spectrometer Dual digital mass flow controllers provide for software control of horizontal purge gas flow rate (up to 1 liter/min.) and automated switching of purge gas. Data analysis provides the ability to plot weight-corrected (normalized) heat flow to insure accurate heat flow measurements during transitions which involve weight changes. Mass Spectrometer (Thermostar GSD 301T) performs qualitative analysis of all gases evolving during thermal analysis; simultaneous data acquisition from a thermal analyzer via Analog Input Module (e.g. temperature, sample weight, differential weight loss); presentation of mass spectrometric data as a function of the thermobalance temperature.
PRODUCER:
TA Instruments
PRODUCTION YEAR:
2008
COMMISSIONING DATE:
PRICE RANGE (at the time of purchase)
DATA SHEET:
Download data sheet file (69.65 kb)
Dynamical Mechanical Analysis (DMA)
CATALOG NAME:
TA Q800
DESCRIPTION:
The DMA has the ability to program stress or force, and strain or amplitude in oscillation experiments. The DMA also allow the following control features: - the Stabilization and Data Collection Cycles allow better control of data collection; - the Stress/Force Accuracy option allows you to specify how close you need to be to the target stress or force. (Applies to the Multi-Stress & Multifrequency-Stress modes); - the option Collect Data when Stable allows you to in experiments on samples with rapidly changing properties. (Applies to the Multi-Strain & Multifrequency Strain modes); - the Go to Temperature option allows the DMA furnace to go to a sub-ambient temperature without starting the run so that the clamps can be retightened to better grip the sample after shrinkage. Allowable temperatures: -150°C to 20°C.
PRODUCER:
TA Instruments
PRODUCTION YEAR:
2008
COMMISSIONING DATE:
PRICE RANGE (at the time of purchase)
DATA SHEET:
Download data sheet file (67.53 kb)
Fourier Transform Infrared Spectrometer (FT-IR)
CATALOG NAME:
Tensor 37
DESCRIPTION:
The TENSOR 37 is an advanced flexible benchtop FT-IR spectrometer designed for the routine lab as well as for demanding analytical laboratory applications. Measurement methods available for the analysis of samples using IR spectroscopy are: transmission, ATR (attenuated total reflection) and low volume liquid cell. Transmission analysis requires some preparation of the sample to ensure that the sample is optically thin. ATR mode usually requires little to no sample preparation. The ATR system is provided with Golden Gate diamond ATR unit, bonded into a tungsten carbide mount, impermeable non-allowing the lenses system condensation. Applications: high absorptive samples, pellets & powders, refracting or opaque solids, simple & coated fibers, corrosive liquids, coatings, ceramics, polymers and plastics, sensitive samples. Liquid cell with CaF2 windows can be used also for viscous liquids and sample prepared with Nujol.
PRODUCER:
Bruker
PRODUCTION YEAR:
2005
COMMISSIONING DATE:
PRICE RANGE (at the time of purchase)
DATA SHEET:
Download data sheet file (73.75 kb)
UV-VIS Spectrophotometer
CATALOG NAME:
Nicolet Evolution 500
DESCRIPTION:
The Nicolet Evolution 500 is a double beam spectrophotometer built around a robust aluminum base casting. Wavelength accuracy is achieved by software compensation. The calibration routine finds 9 predefined emission lines over the wavelength range using Mercury and Deuterium lamps, and uses these to characterize the instrument and so calculate the correct motor position for the required wavelength. The standard scan speed options allow the setting of fixed scan speeds. The maximum rate at which the spectrophotometer can scan is 1200 data points per minute. By slowing the scan speed and/or increasing the data interval the integration time can be increased and consequently noise decreased. The VISIONpro Software Applications offer the possibility of using different working modes such as: Fixed Application, Quant, Multicomponent Analysis (MCA).
PRODUCER:
Thermo Electron Corporation
PRODUCTION YEAR:
2005
COMMISSIONING DATE:
PRICE RANGE (at the time of purchase)
DATA SHEET:
Download data sheet file (70.85 kb)
Phone:
+40213163093
Fax:
+40213123493
Spl. Independentei
,
202
,
Bucharest
060021
,
Bucuresti - Sector 6
Romania
Loading Infrastructure